Author(s): Gabeler Edward | van Hillegersberg Richard | Statius van Eps Randolph | Sluiter Wim | Gussenhoven Elma | Mulder Paul | van Urk Hero
Journal: BMC Cardiovascular Disorders
ISSN 1471-2261
Volume: 2;
Issue: 1;
Start page: 16;
Date: 2002;
Original page
Keywords: balloon injury | rats | remodelling | restenosis
ABSTRACT
Abstract Background Balloon injury (BI) of the rat carotid artery (CCA) is widely used to study intimal hyperplasia (IH) and decrease in lumen diameter (LD), but CCA's small diameter impedes the evaluation of endovascular therapies. Therefore, we validated BI in the aorta (AA) and iliac artery (CIA) to compare it with CCA. Methods Rats underwent BI or a sham procedure (control). Light microscopic evaluation was performed either directly or at 1, 2, 3, 4 and 16 weeks follow-up. The area of IH and the change in LD (LD at 16 weeks minus LD post BI) were compared. Results In the BI-groups the area of IH increased to 0.14 ± 0.08 mm2 (CCA), 0.14 ± 0.03 mm2 (CIA) and 0.12 ± 0.04 mm2 (AA) at 16 weeks (NS). The LD decreased with 0.49 ± 0.07 mm (CCA), compared to 0.22 ± 0.07 mm (CIA) and 0.07 ± 0.10 mm (AA) at 16 weeks (p < 0.05). The constrictive vascular remodelling (CVR = wall circumference loss combined with a decrease in LD) was -0.17 ± 0.05 mm in CIA but absent in CCA and AA. No IH, no decrease in LD and no CVR was seen in the control groups. Conclusions BI resulted in: (1.) a decrease in LD in CCA due to IH, (2.) a decrease in LD in CIA due to IH and CVR, (3.) no change in LD in AA, (4.) Comparable IH development in all arteries, (5.) CCA has no vasa vasorum compared to CIA and AA, (6.) The CIA model combines good access for 2 F endovascular catheters with a decrease in LD due to IH and CVR after BI.
Journal: BMC Cardiovascular Disorders
ISSN 1471-2261
Volume: 2;
Issue: 1;
Start page: 16;
Date: 2002;
Original page
Keywords: balloon injury | rats | remodelling | restenosis
ABSTRACT
Abstract Background Balloon injury (BI) of the rat carotid artery (CCA) is widely used to study intimal hyperplasia (IH) and decrease in lumen diameter (LD), but CCA's small diameter impedes the evaluation of endovascular therapies. Therefore, we validated BI in the aorta (AA) and iliac artery (CIA) to compare it with CCA. Methods Rats underwent BI or a sham procedure (control). Light microscopic evaluation was performed either directly or at 1, 2, 3, 4 and 16 weeks follow-up. The area of IH and the change in LD (LD at 16 weeks minus LD post BI) were compared. Results In the BI-groups the area of IH increased to 0.14 ± 0.08 mm2 (CCA), 0.14 ± 0.03 mm2 (CIA) and 0.12 ± 0.04 mm2 (AA) at 16 weeks (NS). The LD decreased with 0.49 ± 0.07 mm (CCA), compared to 0.22 ± 0.07 mm (CIA) and 0.07 ± 0.10 mm (AA) at 16 weeks (p < 0.05). The constrictive vascular remodelling (CVR = wall circumference loss combined with a decrease in LD) was -0.17 ± 0.05 mm in CIA but absent in CCA and AA. No IH, no decrease in LD and no CVR was seen in the control groups. Conclusions BI resulted in: (1.) a decrease in LD in CCA due to IH, (2.) a decrease in LD in CIA due to IH and CVR, (3.) no change in LD in AA, (4.) Comparable IH development in all arteries, (5.) CCA has no vasa vasorum compared to CIA and AA, (6.) The CIA model combines good access for 2 F endovascular catheters with a decrease in LD due to IH and CVR after BI.