RIBBED DOUBLE PIPE HEAT EXCHANGER: ANALYTICAL ANALYSIS

ADD TO MY LIST
 
Author(s): HUSSAIN H. AL-KAYIEM | MOHAMED F. EL-RAHMAN

Journal: Journal of Engineering Science and Technology
ISSN 1823-4690

Volume: 6;
Issue: 1;
Start page: 39;
Date: 2011;
VIEW PDF   PDF DOWNLOAD PDF   Download PDF Original page

Keywords: Double pipe heat exchangers | Heat transfer enhancement | Ribbing | Counter flow

ABSTRACT
This paper presents the findings obtained by modeling a Double Pipe Heat Exchanger (DPHE) equipped with repeated ribs from the inside for artificial roughing. An analytical procedure was developed to analyze the thermal and hydraulic performance of the DPHE with and without ribbing. The procedure was verified by comparing with experimental reported results and they are in good agreement. Several parameters were investigated in this study including the effect of ribs pitch to height ratios, P/e= 5, 10, 15, and 20, and ribs to hydraulic diameter ratios, e/Dh= 0.0595, 0.0765, and 0.107. These parameters were studied at various operating Reynolds number ranging from 2500 to 150000. Different installation configurations were investigated, too. An enhan-cement of 4 times in the heat transfer in terms of Stanton number was achieved at the expense of 38 times increase of pressure drop across the flow in terms of friction facto values.